combined cycle-power station
Definition

This type of plant is flexible in response and can be built in the 100-600 MW capacity range. It produces electrical power from both a gas turbine (ca. 1300°C gas inlet temperature), fuelled by natural gas or oil plus a steam turbine supplied with the steam generated by the 500°C exhaust gases from the gas turbine. The thermal efficiency of these stations is ca. 50 per cent compared with a maximum of 40 per cent from steam turbine coal fired power stations. This type of plant can be built in two years compared with six years for a coal-fired station and 10-15 years for nuclear.